eWeighBar 600 and 800
How to set up your eWeighBar 600 or 800 out of the box
What's in the box?
You'll receive two eWeighBar 600s or 800s in the box.
Each bar has a cable at one end to be plugged into your weigh head.
The eWeighBar cables come wrapped in a protective wire to help protect them during use.
Each bar is supplied with two M10 bolts for mounting to a weigh platform or crate.
Anchor bolts are not supplied for the feet.
Getting around
Example Weighing System
The weighing system below shows the eWeigh weigh head and 2 weigh bars. The 600 or 800 weigh bars are fitted beneath a platform or handling crate and transmit the weight signal to the weigh head via the cables.
The eWeighBars will connect to a variety of third party weigh heads as well as iLivestock eWeigh and eWeighDS weigh heads.
The weigh head connects via bluetooth to your phone or tablet to record weights in the iLivestock app.
Installing the eWeighBar 600s or 800s
WARNING - LOAD BARS ARE HEAVY!
Wear steel-capped boots/shoes and safety glasses when handling the load bars.Ensure that your lifting equipment is strong enough to lift the handling system or platform so you can safely install the weigh bars.
Step 1. Choose the location for the load bars and platform. Select a firm and level site free of any obstacles, with space around the platform or crate.
A concrete pad is ideal.
Step 2. Apply grease to the four M10 x 40 bolts supplied, then bolt the platform or crate to the weigh bars. The grease will make it easier to remove the load bars at a later date, if required.
Step 3. We recommend that you anchor the platform or crate in place to stop movement. However, in non-permanent applications, you can use it without anchoring, but during use, pay careful attention to any movement.
CAUTION: Dropping the load bars can cause damage.
Do not weld the platform or crate while the load bars are attached.
Testing
Once installed you should test the eWeighBars
Step 1. Connect the weigh bar cables to the eWeigh or compatible weigh scale.
Step 2. Turn on and zero the weigh head.
Step 3. Put a test weight (we recommend tractor weights or another known weigh) at one end of the platform or crate and note the stable reading on the weigh head.
Step 4. Put the test weight at the other end of the platform or crate and note the stable reading on the weigh head.
Step 5. Remove the test weight and note whether the reading returns to zero.
Step 6. If the two readings differ by more than 1kg OR the reading does not return to zero, see the Troubleshooting section.
We recommend you repeat the above tests during use (and also before first use) if the equipment has not been used for some time.
Troubleshooting
|
Fault |
Remedy |
|
Reading does not return to zero between animals
OR
Difference in readings at each end of platform
OR
Under readings (readings lighter than expected) |
|
|
Reading is unstable |
|
|
Reading moves, display shows under load or overload. |
|
Maintenance and Care
- Ensure underneath the platform or crate and the gap between the load bar housing and foot are kept free of dirt and stones.
- Do not allow the weigh head, load bars or plugs to be immersed in water.
- Cables should be placed so that they will not be damaged. We recommend routing the cables through a plastic pipe or other conduit to help prevent damage.
- When not in use, always replace the dust caps on the load bar plugs. When the load bars are connected to the indicator screw, the dust caps are tightened to prevent water from entering them.