Skip to content
English - United Kingdom
  • There are no suggestions because the search field is empty.

eWeighBar 600 and 800

How to set up your eWeighBar 600 or 800 out of the box

This guide will take you through the installation and use of your eWeighBar 600 and 800 load bars. 
 

What's in the box?

You'll receive two eWeighBar 600s or 800s in the box.

Each bar has a cable at one end to be plugged into your weigh head.

The eWeighBar cables come wrapped in a protective wire to help protect them during use.

Each bar is supplied with two M10 bolts for mounting to a weigh platform or crate.

Anchor bolts are not supplied for the feet.

Getting around

Example Weighing System

The weighing system below shows the eWeigh weigh head and 2 weigh bars. The 600 or 800 weigh bars are fitted beneath a platform or handling crate and transmit the weight signal to the weigh head via the cables.

The eWeighBars will connect to a variety of third party weigh heads as well as iLivestock eWeigh and eWeighDS weigh heads.

The weigh head connects via bluetooth to your phone or tablet to record weights in the iLivestock app.

Installing the eWeighBar 600s or 800s

WARNING - LOAD BARS ARE HEAVY!

Wear steel-capped boots/shoes and safety glasses when handling the load bars.

Ensure that your lifting equipment is strong enough to lift the handling system or platform so you can safely install the weigh bars.

Step 1. Choose the location for the load bars and platform. Select a firm and level site free of any obstacles, with space around the platform or crate.

A concrete pad is ideal.

Step 2. Apply grease to the four M10 x 40 bolts supplied, then bolt the platform or crate to the weigh bars. The grease will make it easier to remove the load bars at a later date, if required.

Step 3. We recommend that you anchor the platform or crate in place to stop movement. However, in non-permanent applications, you can use it without anchoring, but during use, pay careful attention to any movement.

CAUTION: Dropping the load bars can cause damage.

Do not weld the platform or crate while the load bars are attached.

Testing

Once installed you should test the eWeighBars

Step 1. Connect the weigh bar cables to the eWeigh or compatible weigh scale.

Step 2. Turn on and zero the weigh head.

Step 3. Put a test weight (we recommend tractor weights or another known weigh) at one end of the platform or crate and note the stable reading on the weigh head.

Step 4. Put the test weight at the other end of the platform or crate and note the stable reading on the weigh head.

Step 5. Remove the test weight and note whether the reading returns to zero.

Step 6. If the two readings differ by more than 1kg OR the reading does not return to zero, see the Troubleshooting section.

We recommend you repeat the above tests during use (and also before first use) if the equipment has not been used for some time.

Troubleshooting

Fault

Remedy

Reading does not return to zero between animals

 

OR

 

Difference in readings at each end of platform

 

OR

 

Under readings (readings lighter than expected)

  • Ensure that the platform/crate is not touching objects that may alter the weights. Typical causes are binding against fixed metal work or build up of dirt.
  • Check that the load bar feet are sitting evenly on the ground
  • Check that bolt holes are not misaligned, as this may put residual load on the weigh bars

Reading is unstable

  • Moisture in the load bar connectors. 
  • Damaged cable. Return the load cell for servicing
  • Moisture in load cells. Return load cells for servicing

Reading moves, display shows under load or overload.

  • Damaged cable return for service

Maintenance and Care

  • Ensure underneath the platform or crate and the gap between the load bar housing and foot are kept free of dirt and stones.
  • Do not allow the weigh head, load bars or plugs to be immersed in water.
  • Cables should be placed so that they will not be damaged. We recommend routing the cables through a plastic pipe or other conduit to help prevent damage. 
  • When not in use, always replace the dust caps on the load bar plugs. When the load bars are connected to the indicator screw, the dust caps are tightened to prevent water from entering them.