eWeighBar HD
How to set up your eWeighBar HD out of the box
What's in the box?
You'll receive two eWeighBar HDs in the box.
Each weigh bar comes with a cable at one end to be plugged into your weigh head.
The eWeighBar cables come wrapped in a protective wire to help prevent damage during use.
4 x hex bolts, including nuts and washers, for bolting the bars to the crush.
4 x anchor bolts, including nuts and washers, for bolting the bars to the floor.
What you need
- Lifting equipment to lift your crush safely.
- Power drill.
- A 12 mm (1/2") masonry drill.
- Hammer.
- Socket set.
- Adjustable spanner.
- Level.
- Cable ties.
- A torque wrench with a 12mm (7/66*) fitting (optional). A torque wrench will only be needed if you swivel the load bar feet and tighten them up again.
- A weigh head such as the iLivestock eWeigh/eWeighDS or another compatible weigh head.
You may also need adaptor plates to install the eWeighBar HDs under your crush. Adapt the length of the bolts for the load bar mounting plates accordingly.
If you don't want the load bar feet to extend beyond the load bar, you can loosen the bolt in the centre of the load bar foot, swivel the foot around, and tighten with a torque wrench on setting of 50 N'm (37 ft-lbs).
Weighing System
The iLivestock weighing system consists of the eWeigh weigh scale and two weigh bars. The weigh bars are fitted beneath a crush, chute or crate and transmit the weight signal to the weigh head via the cables. The eWeighBar HDs can be used with any compatible weigh head.
Installing the HD weigh bars
WARNING: WEIGH BARS ARE HEAVY!
- Wear steel-capped boots/shoes and safety glasses when handling the weigh bars
- Ensure that your lifting equipment is strong enough to lift the chute so you can safely install the weigh bars.
IMPORTANT Dropping the crush with weigh bars fitted or dropping the crush onto the weigh bars will damage them!
How to fit the eWeighBar HDs step by step
Step 1. Lift one end of the crush so that one weigh bar can be positioned underneath.
Step 2. Slide the weigh bar underneath the crush. Align the holes of the weigh bar mounting plate to the holes in the crush, then slowly lower the crush so that it almost touches the weigh bars. Realign the holes as necessary, and affix the weigh bars with the supplied hex bolts at one end, and then the other. Tighten the nut and slowly lower the crush completely onto the weigh bars.
Step 3. Lift the other end of the crush just high enough to slide the second weigh bar underneath the crush and repeat the installation.
Step 4. Using the hammer drill and masonry bit, drill one hole into the concrete pad using a hole in one of the feet as a guide, then bolt down to the concrete using the supplied anchor bolts.
Step 5. Feed the indicator cable through the plastic casing/conduit, then attach the casing/conduit to the crush with cable ties, avoiding the weigh bar feet.
Step 6. Connnect the weigh bar cables to your weigh head.
Testing
Once installed you should test the eWeighBars
Step 1. Connect the weigh bar cables to the eWeigh or compatible weigh scale.
Step 2. Turn on and zero the weigh head.
Step 3. Put a test weight (we recommend tractor weights or another known weigh) at one end of the platform or crate and note the stable reading on the weigh head.
Step 4. Put the test weight at the other end of the platform or crate and note the stable reading on the weigh head.
Step 5. Remove the test weight and note whether the reading returns to zero.
Step 6. If the two readings differ by more than 1kg OR the reading does not return to zero, see the Troubleshooting section.
We recommend you repeat the above tests during use (and also before first use) if the equipment has not been used for some time.
Troubleshooting
See common troubleshooting tips below:
|
Fault |
Remedy |
|
Reading does not return to zero between animals
OR
Difference in readings at each end of platform
OR
Under readings (readings lighter than expected) |
|
|
Reading is unstable |
|
|
Reading moves, display shows under load or overload. |
|
Maintenance and Care
- Ensure underneath the platform or crate and the gap between the load bar housing and foot are kept free of dirt and stones.
- Do not allow the weigh head, load bars or plugs to be immersed in water. Ensure when stored they will be kept dry.
- Cables should be placed so that they will not be damaged. We recommend routing the cables through a plastic pipe or other conduit to help prevent damage.
- When not in use, always replace the dust caps on the load bar plugs. When the load bars are connected to the indicator screw, the dust caps are tightened to prevent dust or rain from entering them.